High Voltage Low Capacity PD Free Test Set

High Voltage Low Capacity PD Free Test Set

Crafted specifically to assess the integrity of electrical components, AC High Voltage Low Capacity Testers are built to meet stringent National and International standards. 

These testers ensure consistent performance and exceptional quality by undergoing rigorous testing at every stage of manufacturing. Available in air-cooled, oil-cooled, or even a combination of both configurations, they deliver a powerful punch with voltage capabilities up to 800 kV and current capacities up to 200 KVA. These versatile testers boast a comprehensive range of testing functions, including dry withstand, wet withstand, breakdown voltage in various environments, and even pollution tests.

  • Lightweight design.
  • Casted wheel for easy movement.
  • Multi-level safety features protect users.
  • Specially designed for field operation.

Standard Accessories

  • Interconnecting control cable.
  • Discharge rod.
  • Audio visual alarm indicator.
  • Corona shield.

Optional Accessories

  • Output HV cable.
  • Interconnecting/input power cable.
  • Earthling lead.
  • Canvas cover.
  • LV Transformer Oil.
Parameter Description
1 Input Voltage 220/230 or 380/400V, 50/60HZ AC Supply
2 Output Voltage Up to 800KV and 400MA
Integration of reactor after 100KVA, 
3 Partial Discharge Level Less than 2pC up to 300kV and less than 10pC up to 600kV
4 Capacity Up to 3000kVA
5 Timer 0-9999 Sec./min. Digital
6 Control Manual Control Manual or motorized voltage adjustment with push-button HT activation.
Digitized Control Digital panel with optional computer connectivity.
PLC based Fully automated: PLC-based system with integrated computer, HMI, and printing capabilities.
7 Metering Voltmeter: One digital type connected on the HT side to indicate the output voltage. Scale: 0-800 kV AC. Ammeter: One digital type ammeter connected on the earth side to indicate the leakage Current on the sample under test. Scale: 0-40A Applicable only for type -1 i.e. for manual control. For type -2 (Digitized Control) and type 3 (PLC Based Model), metering is self-contained.
8 Protection Tripping A rapid DC relay cuts power when the current surpasses the set limit.
Overload Serves as a backup safeguard against input load overage.
Overvoltage Acts as a secondary defense if the output voltage exceeds the threshold.
9 Interlocking Zero Start Interlock The unit will have zero start interlocking to avoid the transients on the HV transformer and provision for cage door interlocking shall also be provided.
Earth Interlock It ensures that HV will not actuate until good earthing is not provided
10 Termination The HT output on suitable HT insulators and other points at earth potential will be brought out on suitable insulator
11 Control Panel The control panel is designed for five unique purposes. 1 – Control 2 – Measure 3 – Protect (Active and Passive) 4 – Tripping 5 – Annunciate
12 Reactor Our Parallel/Series Reactor (LT and HT) harmonizes with capacitive currents during dielectric testing. Featuring a motorized moving coil and fixed reactor, it achieves a Q-factor of up to 20, ensuring precise resonance for various components and systems.
13  HV Transformer We craft our transformers to IS/IEC standards, offering single and multi-stage step-up options for versatile voltage requirements. Built with premium materials sourced globally, our units boast vacuum-impregnated coils insulated with top-tier EHV grade oil, meeting or exceeding industry benchmarks.