‘RE’ Impulse Generators operate in a controlled manner.
How does it work?
A dedicated unit charges the generator, allowing users to set the charging time and voltage. Once the desired voltage is reached, a trigger pulse initiates a firing sequence that starts with the lowest spark gap in the generator. As each spark gap fires in sequence, the interconnected stages effectively multiply the charging voltage. Finally, an impulse voltage divider reduces this high voltage to a level that can be safely measured and recorded by instruments.
Standard Accessories
Optional Accessories
Impulse Voltage Generator | |||
Parameter | Description | ||
1 | Input Voltage | 380/400V. 50/60HZ | |
2 | Rated Voltage | Upto +500kV | |
3 | Rated Capacity | 50kJ | |
4 | Number of Stages | Upto 5 | |
5 | Stage Capacitance | 1.0μF/100kV | |
6 | Stage Energy | Variable | |
7 | DC Voltage Generator | 100kV | |
8 | Impulse Voltage Measurement | Direct Voltage Measurement | |
9 | Polarity Reversal | Motorized / Manual | |
10 | Waveform Measurement | By Impulse Analyzing Software. | |
11 | Safety Features | Safety Interlock | Alarm, generator auto grounding, over current, over-voltage, and phase protection, emergency stop. |
Triggering | Manual and automatic trigger arrangement, Triggering signal can be time delayed. | ||
Auto charge function | Constant current charging; Regulation of charging voltage, charging, and time; Charging control in manual or auto. | ||
Action Control | The sphere gap follows the charging voltage value automatically. | ||
Parameter Setting | The gap adjustment is manual/motorized. DC charge voltage, charge time, discharge sphere gap, Operation triggering mode, polarity switch, etc. |
Copyright 2024 Rectifiers & Electronics Pvt. Ltd. All Rights Reserved.