Primary Current Injection Test Set - Single Phase

Primary Current Injection Test Set - Single Phase

Primary Current Injection Test Sets are essential for the loading, calibration, and testing of CTs, bimetal relays, protection relays, and similar equipment. Typically, these sets are custom-designed according to customer specifications. 

How do they work?

They operate on a duty cycle of 15 minutes on and 30 minutes off, dedicated solely to testing purposes. The loading transformers are specifically designed for continuous operation to manage temperature rise or for use in bus ducts and bus bars. Optional accessories might include cable terminations, timers, temperature indicators, multiple contactors, and individual phase controls. These equipment are compact and come in portable trolley or stationary models, capable of handling currents up to 25,000 amps, with optional digital or analogue timers available.

  • Supply up to 25000 Amps.
  • Electronic parameter monitoring.
  • Multiple safety interlocks for the operator.
  • Tough design for on-site use.

Standard Accessories

  • Interconnecting Control Cable for Split Units.
  • Trolley for split units.

Optional Accessories

  • Output cable.
  • CT Clamp.
  • Canvas Cover.
Parameters Description
1 I/p Voltage  220/230V Single phase or two phase 50/60HZ AC Supply 
2 O/p Current Up to 25000 A
3 Capacity Up to 100 KVA
4 Duty Cycle  Intermittent or continuous
5 Control 1) Adjust current manually or with motorized controls. Simple push-button operation available. 2) Features microprocessor control with built-in digital display panel. 3) Optional PLC system includes a computer, HMI memory, printer, etc.
6 Power Components 1) Step down transformer: 1 No. double wound transformer shall be used for supplying high Current and low voltage for testing. 2) Auto Transformer: 1 No. A motorized Auto Transformer shall be used for controlling the output voltage from zero to maximum to control the load Current.
7 Metering 1) Ampere meter : 1 No. Digital Amperemeter shall be provided with 0.5 classes CT to indicate the output current. The size of the amperemeter shall be 96 sq.mm, one in case of single phase unit. 2) Voltmeter: A digital voltmeter with a selector switch shall be provided to indicate the output voltage from each phase/phase to phase, if required. 3) Line On Indicato: Neon lamp indicators are provided for input indication. 4) Main ON/OFF switch: Two pole ON/OFF are provided for input ON or OFF. 5) Option for XCT current measurement and input current measurement.
8 Termination Output is brought on Copper bus-bars 
9 Control Panel (i) ON/OFF switch (ii) Separate Indication lamp (iii) Digital Output Ampere meter and Voltmeter. (iv) Knob / Push button for raising and lowering the output current.
10 Regulating Transformer Suitable for motorized or manual operation with limit switches. Features lifting mechanism for regulating transformers and entire unit. Includes input and output indicators.
11 Step Down Transformer Air-cooled transformer.  Primary winding: DCC insulated.  Secondary: bare copper strip. MS sheet housing on angle iron frame.  Output: electrolyte-grade copper busbar.