Inductive Load Bank

Inductive Load Bank

Load Banks are crafted for conducting load tests on single-phase and three-phase AC/DC power supplies, diesel generators, UPS systems, and inverters, among other equipment. 

We offer load banks with capacities up to 3000kW, compatible with single-phase 230V ±5% and three-phase 400V ±5% 50Hz AC supplies. The power factor for AC can be adjusted between 0.2 lagging to unity and 0.3 leading. Our load banks range from 5kW to 3000kW and come in both stepped and stepless versions, with manual, semi-automatic, and fully automatic control options. Additionally, digital multi-function meters are provided to display voltage, current, wattage, KVAr, and power factor.

These load banks are designed for continuous operation and cooled using forced air, with an auxiliary supply featuring independent controls.

We manufacture for the following types of Loads:

  • Resistive Loads.
  • Inductive Loads.
  • Capacitive Loads.
  • Resistive/Inductive Combined Loads.
  • Resistive/Inductive/Capacitive Combined Loads.


Each load bank consists of coarse and fine controls as per the specific requirements.

  • Multiple safety interlocks.
  • Computer interface facility.
  • Full automation options offered.
  • Built-in operator safety features
  • Compact design.
  • Cascade-style configuration.
  • Temperature sensors in Load Bank centers.
  • Load ON-OFF switches with status indicators.
  • Our inductive loads operate silently.
  • Fans installed based on unit needs.
  • Illuminated buttons for load control.
  • Fine-tuning Load Bank via push button.
  • Adapts to new technologies.
  • Expandable to higher capacities.
  • Versatile design for various environments.
  • IP44 rated protection.
  • Single unit capacity up to 1000kW at 0.6 PF.
  • Low heat output, max 150°C operation.
  • Functions in ambient temps up to 55°C.
  • Air-conditioned control room, powered by AUX or load supply.

Standard Accessories

  • Discharge rod for Capacitive Load Bank

Optional Accessories

  • Trolley Based System
  • Container Based System
  • All weather system
  • PLC based system
Parameters Resistive Load Bank Inductive Load Bank Capacitive Load Bank
1 Capacity 5kW to 3000kW 5kW to 3000kW 5kW to 3000kW
2 Input Supply Voltage 220/230V, 50/60HZ or 380/400V, 50/60HZ Supply 220/230V, 50/60HZ or 380/400V,50/60HZ Supply 220/230V,50/60HZ or 380/400V, 50/60HZ Supply
3 Frequency 50HZ/60HZ 50HZ/60HZ 50HZ/60HZ
4 Cooling  Forced Air Forced Air Forced Air
5 Controls MCB / Contactor Based  MCB / Contactor Based  MCB / Contactor Based 
  PLC Based PLC Based PLC Based
6 Material Used SS-304 / Nichrome  Standard inductors Standard Capacitors