Resistive Load Bank

Resistive Load Bank

Imagine a toolbox specifically designed to push your power equipment to its limits. That’s what our load banks are – versatile testers built to handle single-phase or three-phase AC/DC systems, from diesel generators to inverters. We offer a range of options, from compact 5kW models to heavy-duty 3000KW workhorses. 

Whether you need to test a 230V single-phase supply or a 400V three-phase setup, we’ve got you covered. And the control is all yours – choose from manual, semi-automatic, or fully automatic operation. No matter the test, our load banks can handle it, with an adjustable power factor and digital meters that track voltage, current, and more. Built for continuous operation and cooled by powerful fans, these load banks are ready to tackle any testing challenge you throw their way.

We manufacture following types of Loads :

  • Resistive Loads.
  • Inductive Loads.
  • Capacitive Loads.
  • Resistive/Inductive Combined Loads.
  • Resistive/Inductive/Capacitive combined Loads.

Each load bank consists of coarse and fine controls as per the specific requirements.

  • Multiple safety interlocks.
  • Computer interface facility.
  • Full automation options offered.
  • Built-in operator safety features
  • Compact design.
  • Cascade-style configuration.
  • Temperature sensors in Load Bank centers.
  • Load ON-OFF switches with status indicators.
  • Our inductive loads operate silently.
  • Fans installed based on unit needs.
  • Illuminated buttons for load control.
  • Fine-tuning Load Bank via push button.
  • Adapts to new technologies.
  • Expandable to higher capacities.
  • Versatile design for various environments.
  • IP44 rated protection.
  • Single unit capacity up to 1000kW at 0.6 PF.
  • Low heat output, max 150°C operation.
  • Functions in ambient temps up to 55°C.
  • Air-conditioned control room, powered by AUX or load supply.

Standard Accessories

  • Discharge rod for Capacitive Load Bank

Optional Accessories

  • Trolley Based System
  • Container Based System
  • All weather system
  • PLC based system
Parameters Resistive Load Bank Inductive Load Bank Capacitive Load Bank
1 Capacity 5kW to 3000kW 5kW to 3000kW 5kW to 3000kW
2 Input Supply Voltage 220/230V, 50/60HZ or
380/400V, 50/60HZ Supply
220/230V, 50/60HZ or
380/400V, 50/60HZ Supply
220/230V, 50/60HZ or
380/400V, 50/60HZ Supply
3 Frequency 50HZ/60HZ 50HZ/60HZ 50HZ/60HZ
4 Cooling  Forced Air Forced Air Forced Air
5 Controls MCB / Contactor Based  MCB / Contactor Based  MCB / Contactor Based 
  PLC Based PLC Based PLC Based
6 Material Used SS-304 / Nichrome  Standard inductors Standard Capacitors

Sign-up for our newsletter